Ways to prevent water freezing in the pipes
Installation of underfloor heating can take a plumber. It will cooperate with our stove central heating. Once you have underfloor heating we must remember, to prevent freezing of water remaining in the pipes during the winter, which will not be used out of the house, and thus, give up its heating and incurring the related fees. We must remember that the consequences of the absence of such heating can prove to be fatal and freezing water can lead to cracks in the tiles in the room where we installed floor heating. One of the ways to prevent freezing of water pipes will be delivered to the special antifreeze fluid and accurate closing of the water valve shut off the water supply.
Boiler - accessories
Pressuretrols to control the steam pressure in the boiler. Boilers generally have 2 or 3 pressuretrols: a manual-reset pressuretrol, which functions as a safety by setting the upper limit of steam pressure, the operating pressuretrol, which controls when the boiler fires to maintain pressure, and for boilers equipped with a modulating burner, a modulating pressuretrol which controls the amount of fire.
Safety valve: It is used to relieve pressure and prevent possible explosion of a boiler.
Water level indicators: They show the operator the level of fluid in the boiler, also known as a sight glass, water gauge or water column.
Bottom blowdown valves: They provide a means for removing solid particulates that condense and lie on the bottom of a boiler. As the name implies, this valve is usually located directly on the bottom of the boiler, and is occasionally opened to use the pressure in the boiler to push these particulates out.
Continuous blowdown valve: This allows a small quantity of water to escape continuously. Its purpose is to prevent the water in the boiler becoming saturated with dissolved salts. Saturation would lead to foaming and cause water droplets to be carried over with the steam ? a condition known as priming. Blowdown is also often used to monitor the chemistry of the boiler water.
Flash tank: High-pressure blowdown enters this vessel where the steam can 'flash' safely and be used in a low-pressure system or be vented to atmosphere while the ambient pressure blowdown flows to drain.
Automatic blowdown/continuous heat recovery system: This system allows the boiler to blowdown only when makeup water is flowing to the boiler, thereby transferring the maximum amount of heat possible from the blowdown to the makeup water. No flash tank is generally needed as the blowdown discharged is close to the temperature of the makeup water.
Źródło: https://en.wikipedia.org/wiki/Boiler
Repairs hydraulic
Broken hydraulic pipe is a big problem, which can be very unpleasant consequences. In such situations, it is often flooded our apartment, and destroy various appliances and furniture, and sometimes even applies to our neighbors. Any such situation is impossible to control, however, and you only need to properly go about it. Never should wait until the last minute, and the best start work immediately, when we see that something is wrong. The simplest and best solution in this case the service call, hydraulic, who on the spot to repair the broken pipe and replace specific parts with new ones. It should always be the number of such service at hand.